Polling a PWM Fault Pin on a dsPIC® Digital Signal Controllers (DSCs)

How can an application read the fault pin in order to determine status instead of having the PWM module react and shutdown in response to a fault condition?

  • One possible way would be to disable the PWM fault override and use the fault pin as an interrupt source. The override function is disabled by setting the FLTMOD bits of the register FCLCONx with 0b11. To enable the fault interrupt set the FLTIEN bit of the PWMx register. The fault pin interrupt service routine would be available to take whatever action is needed.
  • The fault pins are readable through the port I/O logic when the High-Speed PWM module is enabled, allowing the application to read the pin values.
© 2025 Microchip Technology, Inc.
Notice: ARM and Cortex are the registered trademarks of ARM Limited in the EU and other countries.
Information contained on this site regarding device applications and the like is provided only for your convenience and may be superseded by updates. It is your responsibility to ensure that your application meets with your specifications. MICROCHIP MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING BUT NOT LIMITED TO ITS CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR PURPOSE. Microchip disclaims all liability arising from this information and its use. Use of Microchip devices in life support and/or safety applications is entirely at the buyer's risk, and the buyer agrees to defend, indemnify and hold harmless Microchip from any and all damages, claims, suits, or expenses resulting from such use. No licenses are conveyed, implicitly or otherwise, under any Microchip intellectual property rights.