Low Power Application on SAM E54 Using Harmony v3 Peripheral Libraries: Step 1

Step 1.1: Verify Whether the MPLAB® Harmony Configurator (MHC) Plugin is Installed in MPLAB X IDE

1

Verify that MHC is installed.

• Launch MPLAB X IDE from the Microsoft Windows® Start menu. Close any projects and files that are currently open.
• Go to Tools > Embedded.
• You will see MPLAB Harmony 3 Configurator in the menu.

mhc_setup.png

If you don't see it in the menu, install MHC.

Step 1.2: Set Up MHC Plugin Window to Open in Standalone Mode

1

Go to Tools > Options. You will see the Options window open.

mhc_launch_mode1.png
mhc_launch_mode2.png

2

Go to Plugins > Window Manager and select Standalone mode. Click Apply and then click OK.

standalone_setup.png
  • When you launch MHC for the first time, it displays a prompt asking for the mode in which you would like to use MHC.
    • Standalone mode (as a separate window)
    • Native mode (as an embedded window in MPLAB X)
  • Standalone mode is the default mode.
  • MHC will launch in the operating mode selected the first time, every time you launch MHC.
  • Step 1.2 above shows a way to change the MHC operating mode.

For this lab, MHC is configured to operate in Standalone mode.

Step 1.3: Create MPLAB Harmony v3 Project Using MPLAB X IDE

1

Select File > New Project from the main IDE menu.

Close all existing opened projects before you start creating a new project.

2

In the Categories pane of the New Project dialog window, select Microchip Embedded. In the Projects pane, select 32-bit MPLAB Harmony 3 Project, then click Next.

project_creation_setup.png

If the 32-bit MPLAB Harmony 3 Project is not displayed, install MHC.

3

Browse to the folder you downloaded the framework to in the Framework Path edit box. If you haven't done this, or want to download it to a different folder, click the Launch Content Manager button, then click Next.

For more information on the content manager, see the "Download MPLAB Harmony Framework" section of the "MPLAB Harmony Configurator Overview" page.

project_path_setup.png

4

In the Project Settings window, apply the following settings:

  • Location: Indicates the path to the root folder of the new project. All project files will be placed inside this folder. The project location can be any valid path, for example: <Your_folder>\dev\same54_low_power.
  • Folder: Indicates the name of the MPLABX .X folder. Enter "sam_e54_xpro" to create a sam_e54_xpro.X folder.
  • Name: Indicates the name of the project that will be shown in MPLAB X IDE. Enter "low_power_sam_e54_xpro" to set the project's name.

Note: The Path box is read-only. It will update as you make changes to the entries.

  • Click Next to proceed to Configuration Settings.
project_naming_setup.png

Clicking on the Show Visual Help button will open a help window, providing a detailed description of the various fields in the Project Settings window.

project_naming_setup_help.png

5

Follow the steps below to set the project’s Configuration Settings.

  • Name: Enter the configuration name as "sam_e54_xpro".
  • Target Device: Select ATSAME54P20A as the target device.

Note: You can select the Device Family or enter a partial device name to filter the list in Target Device to make it easier to locate the desired device.

After selecting the target device, click Finish to launch the MHC.

project_setup_finish.png

The New Project Wizard opens a Configuration Database Setup window to allow you to review the packages that will be used by the current project.

6

Click Launch to launch the MHC tool with the selected packages.

mhc_launch_step.png

The MHC plugin’s main window for the project will be displayed.

launched_mhc_view.png

7

Before proceeding, set up the compiler toolchain. Click on the Projects tab on the top left pane in MPLAB X IDE. Right click on the project name low_power_sam_e54_xpro and go to Properties.

project_view.png

Make sure that XC32 (v2.41) is selected as the Compiler Toolchain for XC32. Click on Apply and then click on OK.

xc32_setup.png

Tool Tip:
If you closed MHC accidently and would like to open it again, go to Tools > Embedded > MPLAB Harmony 3 Configurator in MPLAB X IDE.

Step 1.4: Configure Clock Settings

1

Launch Clock Easy View by going to the Tools menu of the MHC window and then selecting Clock Configuration.

clock_configuration_open.png

A new window, Clock Easy View, is opened inside MHC.

2

The Clock Easy View window will then appear on your screen.

clock_configuration_setup.png

Tool Tip:

  • The Clock Easy View window can be minimized by clicking the minimize button, as shown below.
minimize_button.png
  • After minimizing the Clock Easy View window, you can see a small Clock Easy View tab at the bottom-left in MHC, as shown below.
clock_easy_view_tab.png
  • The Clock Easy View window can be maximized by clicking the maximize button or by double-clicking on the Clock Easy View window, as shown below.
maximize_button.png
  • These tips apply to all other plugin managers like Pin Configuration, Direct Memory Access (DMA) Configuration, Event System Configuration, and Enhanced Vectored Interrupt Controller (EVIC) Configuration.

3

Enable the XOSC CTRL 1 and configure the Oscillator input to 12 MHz.

xosc_ctrl1_config.png

4

Set XOSC1 as GCLK Generator 0 source.

gclk0_selection.png

5

Set OSCULP32K as GCLK Generator 1 source.

gclk1_selection.png

6

Set XOSC1 as GCLK Generator 2 source and set divisor value as 12.

gclk2_selection.png

7

Disable the DFLL and FDPLL.

disable_dfll_fdpll.png



Next Step >

© 2024 Microchip Technology, Inc.
Notice: ARM and Cortex are the registered trademarks of ARM Limited in the EU and other countries.
Information contained on this site regarding device applications and the like is provided only for your convenience and may be superseded by updates. It is your responsibility to ensure that your application meets with your specifications. MICROCHIP MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING BUT NOT LIMITED TO ITS CONDITION, QUALITY, PERFORMANCE, MERCHANTABILITY OR FITNESS FOR PURPOSE. Microchip disclaims all liability arising from this information and its use. Use of Microchip devices in life support and/or safety applications is entirely at the buyer's risk, and the buyer agrees to defend, indemnify and hold harmless Microchip from any and all damages, claims, suits, or expenses resulting from such use. No licenses are conveyed, implicitly or otherwise, under any Microchip intellectual property rights.